BRAND NEW 100 CFM SCHULZ NON CYCLING REFRIGERATED COMPRESSED AIR DRYER FOR AIR COMPRESSORS.WHAT IS A NON CYCLING REFRIGERATED AIR DRYER AND WHY DO I NEED ONE ?
COMPRESSED AIR CONTAINS NATURALLY OCCURRING MOISTURE, WHICH CAN NEGATIVELY AFFECT COMPRESSED AIR APPLICATIONS THAT REQUIRE MOISTURE FREE AIR. DRYERS ARE A COMMON SOLUTION FOR REMOVING SUCH MOISTURE. ONE OF THE MOST POPULAR OPTIONS ARE REFRIGERATED AIR DRYERS, DUE TO ITS ABILITY TO REACH AN ACCEPTABLE DEW POINT IN. NON-CYCLING REFRIGERATED DRYERS, THE REFRIGERANT ACTUALLY CIRCULATES CONTINUOUSLY THROUGHOUT THE SYSTEM. BECAUSE BOTH THE FLOW OF COMPRESSED AIR AND AMBIENT TEMPERATURES VARY, A HOT GAS BYPASS VALVE IS USED TO REGULATE THE TEMPERATURE OF THE
REFRIGERANT WHILE PREVENTING FREEZING WITHIN THE SYSTEM.
PLEASE NOTE:
IT IS VITAL THAT LIQUID WATER AND OIL ARE REMOVED FROM YOUR COMPRESSED AIR LINES BEFORE ENTERING ANY REFRIGERATED AIR DRYER. LIQUID WATER AND/OR OIL FROM YOUR COMPRESSOR CAN DAMAGE THE INTERIOR COMPONENTS OF THE DRYER RESULTING IN DRYER NON-PERFORMANCE OR FAILURE.
AIR TREATMENT SYSTEMS BEFORE THE DRYER ARE NECESSARY:
IF YOU CURRENTLY HAVE SOME SORT OF WATER SEPARATOR OR IN-LINE FILTRATION SYSTEM INSTALLED ON YOUR COMPRESSED AIR SYSTEM, PLEASE MAKE SURE IT IS INSTALLED BEFORE THIS REFRIGERATED AIR DRYER. IF YOU DO NOT HAVE COMPRESSED AIR LINE FILTRATION INSTALLED,
HERE IS OUR EBAY LISTING FOR THIS 100 CFM DRYER UNIT WITH 3 MICRON WATER SEPARATOR FILTER . (
173966797149
). COPY & PASTE ITEM CODE TO YOUR EBAY SEARCH BAR.
WATER SEPARATION AND MOISTURE REMOVAL INFO:
THE MOST EFFECTIVE WAY TO SEPARATE MOISTURE WATER FROM YOUR COMPRESSED AIR IN YOUR COMPRESSED AIR LINES, STARTS WITH THE COMPRESSED AIR LINES THEMSELVES. WHEN YOU ARE SETTING UP OR INSTALLING YOUR PIPING, YOU ALWAYS WANT TO FORCE YOUR COMPRESSED AIR TO CLIMB VERTICALLY, WHILE POOLING LIQUID WATER IS DRIVEN DOWNWARDS BY GRAVITY. USUALLY INTO SOME SORT OF DRAIN OR BALL VALVE THAT IS RELEASED PERIODICALLY. BY DOING THIS, YOU NOT ONLY PROTECT THE REFRIGERATED AIR DRYER AND YOUR PNEUMATIC TOOLS AND SPRAYERS. IF YOU VISIT GOOGLE IMAGES AND SEARCH, "PROPER COMPRESSED AIR LINE INSTALLATION", YOU WILL SEE A WIDE VARIETY OF DIFFERENT INSTALLATION TYPES THAT YOU CAN EMULATE ON YOUR OWN SET UP. YOU CAN ALSO VIEW OUR ATTACHED PICS FOR OUR RECOMMENDED COMPRESSED AIR LINE SET UP WITH FILTERS AND BY PASS.
DRYER SIZING:
WHEN SIZING A DRYER, IT’S IMPORTANT TO UNDERSTAND HOW TEMPERATURE AND PRESSURE AFFECT WATER CONTENT IN AIR. THE WATER VAPOR CONTENT OF AIR VARIES DIRECTLY WITH TEMPERATURE. IF TEMPERATURE INCREASES, THE AIR’S ABILITY TO HOLD WATER INCREASES. AS A RULE OF THUMB, EVERY 20° F RISE IN INLET AIR TEMPERATURE MAY DOUBLE THE WATER LOAD ON A DRYER. PRESSURE IS THE OPPOSITE. THE WATER VAPOR CONTENT OF AIR VARIES INVERSELY WITH PRESSURE—IF PRESSURE INCREASES, IT SQUEEZES MOISTURE OUT. BECAUSE OF THESE TWO RELATIONSHIPS, COMPRESSED AIR DRYERS HAVE CORRECTION FACTORS (PLEASE SEE OUR ATTACHED PICS FOR THE SCHULZ CORRECTION FACTORS) TO HELP DETERMINE HOW MUCH AIR A DRYER CAN ACTUALLY HANDLE FOR SPECIFIC AMBIENT CONDITIONS.
IN SELECTING WHICH CORRECTION FACTORS TO USE, MAKE SURE YOU GO WITH THE WORST CASE SCENARIO. THIS IS USUALLY DURING THE HOTTER, MORE HUMID SUMMER MONTHS. YOU CAN ALSO FIND A VAST AMOUNT OF INFORMATION REGARDING REFRIGERATED AIR DRYER CALCULATORS ONLINE.
ADS-100 NON-CYCLING REFRIGERATED AIR DRYER INFORMATION
EACH UNIT COMES COMPLETE WITH VERY DESCRIPTIVE USERS / OPERATION MANUAL. ITS RECOMMENDED THE USERS MANUAL STAYS IN THE PRESENCE OF THE OPERATOR.
200 PSI MAX INPUT PRESSURE TO THE INLET SIDE OF THE DRYER. THIS 100 CFM DRYER HAS A 1.25" FEMALE NPT INLET AND OUTLET. THE INLET AND OUTLET 1.25" FEMALE NPT CONNECTIONS ON THE DRYER ARE MACHINED ALUMINUM. ONLY USE BRASS OR STEEL MACHINED HEX BUSHINGS OR UNIONS FOR YOU TO USE ON THE INLET AND OUTLET PORTION OF THE REFRIGERATED AIR DRYER. ITS VERY IMPORTANT THAT YOU
DO NOT
USE COARSE BLACK IRON PIPE OR GALVANIZED FITTINGS ON THE ALUMINUM INLET/OUTLET PORTION OF THE DRYER. THE COARSE THREADS CAN DAMAGE THE ALUMINUM FITTINGS WHICH COULD LEAD TO A LEAK IN THE PIPING.
PLEASE REVIEW THE REQUIRED INSTALLATION GUIDELINES BELOW
TECHNICAL INFO:
SINGLE PHASE
CFM: 100 CFM AT 100 PSI
MAX INLET PRESSURE: 200 PSI MAX DRYER
DEW POINT: 41 DEGREES FAHRENHEIT AT 100 PSI
AMBIENT TEMPERATURE: 113 DEGREES FAHRENHEIT MAX 34 DEGREES FAHRENHEIT MINIMUM
CONNECTION: 1.25" FEMALE NPT INLET AND OUTLET.
DEW POINT: 41 DEGREE
FAHRENHEIT, 5 DEGREE CELSIUS.
PLEASE VIEW ATTACHED CORRECTION FACTORS IN OUR ATTACHED PICS.
REFRIGERANT FLUID TYPE: R134a
VOLTAGE: 115V
WIRE SIZE REQUIRED: 14 GAUGE
FREQUENCY: 60hz
DIMENSIONS IN INCHES: ( HEIGHT 29.2" ) ( WIDTH 13.9" ) (LENGTH/DEPTH 17.5")
APPROX WEIGHT: 86 LBS
SINCE COMPRESSED AIR PIPING INSTALLATION SETS UPS VARY IN LENGTH AND SIZE, WE DO NOT PROVIDE ANY OF THE COMPRESSED AIR TUBING YOU WILL NEED IN ORDER TO PLUMB THIS SYSTEM TOGETHER. PLEASE VISIT OUR STORE FOR A VARIETY OF COMPRESSED AIR TUBING OPTIONS. NEVER USE PVC FOR YOUR COMPRESSED AIR LINE INSTALLATIONS. IF PVC RUPTURES, IT CAN SEND DANGEROUS SHARDS AT TREMENDOUS VELOCITIES THROUGHOUT YOUR WORK SPACE CAUSING SERIOUS INJURY.
INSTALLATION REQUIREMENTS FOR ADS SERIES REFRIGERATED AIR DRYERS:
LOCATION:
THE PRODUCT MUST BE INSTALLED IN AN ENGINE ROOM ACCORDING TO NR13 OF MTB, IN A ROOFED AREA THAT IS WELL VENTILATED, FREE FROM DUST, TOXIC GASES, HUMIDITY OR POLLUTION OF ANY KIND. IN ORDER TO REDUCE THE EXCESS OF NOISE, A SOUNDPROOFING PROJECT MUST BE TAKEN INTO CONSIDERATION. FAILURE TO INSTALL DRYER IN THE PROPER AMBIENT CONDITIONS WILL AFFECT THE DRYER’S ABILITY TO CONDENSE REFRIGERANT GAS. THIS CAN CAUSE HIGHER LOADS ON THE COMPRESSOR, LOSS OF DRYER EFFICIENCY AND PERFORMANCE, OVERHEATED CONDENSER FAN MOTORS, ELECTRICAL COMPONENT FAILURE AND DRYER FAILURE DUE TO THE FOLLOWING: COMPRESSOR LOSS, FAN MOTOR FAILURE AND ELECTRICAL COMPONENT FAILURE. FAILURES OF THIS TYPE WILL AFFECT WARRANTY CONSIDERATIONS. IF THE ROOM TEMPERATURE IS OVER THAT, IT IS NECESSARY TO USE THE FLOW CORRECTION TABLE. THIS APPLIES FACTORS WHICH HELP TO FIND OUT THE CORRECTED DISCHARGE THE DRYER IS ABLE TO PROCESS. THE USE OF EXHAUST FANS IS ALSO RECOMMENDED, COOLING DUCTS, OR OTHER MEANS TO PROVIDE A DECREASE IN TEMPERATURE. IF THE ROOM TEMPERATURE IS NEAR OR LESS THAN 5°C, THE SRS - AIR DRYER IS NOT RECOMMENDED, AS HEATING IS REQUIRED FOR THE MACHINE ROOM AND THE ENTIRE COMPRESSED AIR PIPELINE FOR TEMPERATURES AROUND OR OVER 10°C. THE PRESENCE OF CONTAMINATION AGENTS (DUST, FIBERS, ETC.) SUSPENDED IN THE AIR CAN CAUSE PREMATURE OBSTRUCTION OF THE CONDENSER
PLACEMENT:
KEEP DRYER
AWAY FROM ANY OBSTACLE TO AVOID HARMING THE OPERATION AND AT THE SAME TIME FACILITATING PREVENTIVE MAINTENANCE OF THE ADS - AIR DRYER. DRYERS MODELS ADS 10 – 150 CAN BE WALL-MOUNTED. DIMENSIONS ON DIMENSIONAL DRAWINGS ARE SHOWN IN USERS MANUAL. THE HANGING MOUNTING INEVITABLY CAUSES THE OBSTRUCTION OF THE VENTILATION GRID POSITIONED ON THE PANEL FACING THE WALL FIXING. THIS OBSTRUCTION, IN ANY CASE, DOES NOT PREJUDGE THE EFFICIENCY OF THE VENTILATION INSIDE THE DRYER WHICH IS GUARANTEED BY OTHER GRIDS ON THE OTHER PANELS.
FOUNDATION:
THE PRODUCT MUST BE INSTALLED ON A CONCRETE BASE CAPABLE OF SUPPORTING ITS WEIGHT AND THE FORCES RESULTING FROM ITS OPERATION. INSTALL THE ADS - AIR DRYER BY REMOVING THE BASE USED FOR SHIPPING.
COMPRESSED AIR QUALITY:
THE INSTALLATION OF A COALESCENT FILTER OF 1Μ (MICRON) IS INDISPENSABLE IN THE ADS - AIR DRYER INLET FOR THE PURPOSE OF AVOIDING THE ENTRANCE OF OIL AND SOLID PARTICLES WHICH MAY OBSTRUCT OR HARM THE THERMAL EXCHANGE IN THE HEAT EXCHANGER. IF THE AIR PROCESSED BY THE DRYER IS SUPPLIED BY AN ALTERNATING PISTON COMPRESSOR A TOTAL PIPELINE COURSE OF AT LEAST 26 FEET IS RECOMMENDED BETWEEN THE RESERVOIR AND THE DRYER (OR A COALESCENT PRE-FILTER). THIS LENGTH OF PIPELINE HELPS A GREAT DEAL IN COOLING THE COMPRESSED AIR BEFORE GOING INTO THE DRYER. IT DEPENDS ON THE QUALITY OF THE COMPRESSED AIR TO EVALUATE THE NEED OF INSTALLING ONE OR MORE FILTERS. THE PURPOSE IS TO AVOID THE ACCUMULATION OF PARTICLES IN THE LINE.
Terms and Conditions
Payment Information:
VISA / MASTERCARD / AMEX / DISCOVER / PAYPAL accepted.
Contact Us:
Please feel free to contact us anytime through the ebay message board. On each of our ebay listings you will see options to contact us. The "ask seller a question" link and the "Contact seller" link are the two best ways to contact us. Your question will automatically link to your purchase or the item in question and will be answered Mon-Fri during our operating hours.
No ebay question or message goes unanswered.
Please DO NOT contact us via email regarding your ebay purchase.
Return Policy:
Here is how to arrange an ebay return
http://pages.ebay.com/
help/buy/return-item.html
Arrangements must be made within 30 days of purchase.
Returns are permitted only with the prior approval of UPE_Group.
A minimum restocking fee of 15% will be applied on returns due to customer error.
Authorized returns will be credited at the transaction price, minus any applicable fees. The adjusted amount will refunded back to the buyer's payment method after the item has been returned back to UPE_Group.
The above fees will NOT be charged on items returned due to manufacturers’ defect or shipping errors caused by UPE_Group, USPS or FEDEX.
Shipping Address:
We ship to the buyers ebay ship to address. Please make sure your ship to address is correct before checking out.
Domestic Shipping:
We are open Monday through Friday shipping eBay orders
.
All orders ship within 24 BUSINESS Hours of payment confirmation
. We ship most orders the same day that we receive them, just as long as your payment clears before mid afternoon EST. Items are shipped USPS or FEDEX ground. The shipping method will be listed on the shipping/payments tab or underneath the buy-it-now button on all ebay listings. We generate shipping labels through ebay, so your tracking info will be emailed to you the moment your shipping label is generated. You can click the link on your tracking info to get up to date tracking info regarding your shipment. You can find the link on your transaction details page, or under the "Buying" portion on your "My eBay" page. For specific shipping info and combined shipping rules, please click the "shipping and payment" tab on any of our ebay listings. That link will show you the shipping specifics and combined shipping rules relating to that specific item.
International Shipping:
All items we sell are available for international shipping through the ebay 3rd party Global Shipping program. UPE_Group will ship your item to the ebay global shipping center in Kentucky. From there, eBay forwards the package to your international destination.
Please click the shipping/payments tab of our listings for international shipping information or visit this ebay page.
http://pages.ebay.com/
help/buy/shipping-globally.
html
Combined Shipping Rules:
Simply use the ebay shopping cart feature and add items to your cart for one flat shipping rate. eBay's Combined shipping Rules are usually implemented
by all ebay sellers. The only way for eBay to recognize multiple items going to the same address is by using the ebay shopping cart feature. Add items into ONE ebay shopping cart and check out on ONE transaction/purchase. You can also request an invoice from the seller once you have added all of the items into your ebay shopping cart.
Tracking Information:
We provide Tracking info on every item that is purchased on ebay. The tracking info will be emailed to you the day your order is shipped.
Feedback Policies:
Anyone who purchases from us gets positive feedback. If you have any sort of issue with the item you received from us, please contact us before leaving a bad feedback. We would be more than happy to correct any issue. Regardless if we accidentally sent you the wrong item (which seldom happens) or the customer ordered the wrong part by mistake. WE WILL correct any potential problem.
Sales Tax:
The Purchaser shall be responsible for the payment of all state sales taxes.
Liability:
UPE_Group is a dstributor and as such, has no direct or indirect control over the materials, processes, or quality control procedures used by the manufacturers of the products we resell. Accordingly, UPE_Group will NOT be held responsible for damages resulting from product defects, or, from mis-applications/improper installations by the customer or end user. It is the purchasers responsibility to determine the suitability of the product for the specific application.
If it is deemed defective,
UPE_Group shall be held harmless of any and all damages including (but not limited to) physical injury, property damage, water damage or otherwise for any reason.
If the purchased item is deemed defective, UPE_Group will make arrangements to replace the defective item at no additional costs to the customer.
CA Prop 65 WARNING:
Some of the products sold by Universal Pneumatic and Electric Group may contain chemicals known to the State of California, Vermont and others to cause cancer, birth defects, or other reproductive harm. It is the purchasers responsiblity to determine the suitability of these products for your specific application. Including, but not limited to, using alternative products. UPE_Group shall be held harmless of any and all damages including but not limited to physical, property, water or otherwise for any reason. Your use of any information or materials on this listing is entirely at your own risk, for which we shall not be liable.
By submitting your order, the purchaser acknoledges agreement with the Terms & Conditions as outlined here and our website.
PLEASE CONTACT US WITH ANY QUESTION YOU HAVE REGARDING ANY OF OUR PRODUCTS OR TERMS AND CONDITIONS.